Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
No calibration needed. Precisely located, burr-free static pressure holes. Hemispherical tip design, best for accuracy if imperfectly aligned and nearly impossible to damage.
Fast
Shipping
Free
Return*
Secure Packaging
100% Original Products
PCI DSS Compliance
ISO 27001 Certified
What Stands Out
Product Details
| Item Weight | 2 lbs (910 grams) |
Who Should Buy?
-
HVAC Technicians
Ideal for HVAC professionals who need accurate air velocity measurements in duct systems and ventilation applications.
-
Industrial Engineers
Suitable for engineers monitoring airflow in industrial settings, ensuring optimal operational efficiency and system performance.
-
Environmental Scientists
Beneficial for environmental studies where accurate airflow data is vital for assessments of air quality and flow dynamics.
-
Homeowners
Not suitable for casual users, as it requires technical knowledge and calibration for effective use in home environments.
-
Small Scale Projects
Excessively large for minor projects; better tailored for professional and industrial applications requiring precise measurements.
-
Non-Technical Users
May be difficult to operate for those without technical expertise in airflow measurement or HVAC systems.
Product Description
Dwyer Instruments, Inc. 160-18 18 SS Pitot Tube
Customer Questions & Answers
-
Question:
What is the Dwyer Instruments, Inc. 160-18 18 SS Pitot Tube used for?
Answer: The Dwyer Instruments, Inc. 160-18 18 SS Pitot Tube is designed for measuring air velocity in duct systems or open air. This instrument operates by measuring the difference between the total pressure and static pressure in the airflow. It's commonly used in HVAC applications to assess system performance, ensuring efficient air distribution and balancing in ventilation systems. This tool is essential for technicians and engineers who need accurate air flow measurements for optimizing system designs and energy efficiency. -
Question:
What materials are used in the construction of the Dwyer 160-18 Pitot Tube?
Answer: The Dwyer 160-18 Pitot Tube is made from high-quality stainless steel, ensuring durability even in harsh environments. This material choice helps resist corrosion, making it suitable for various applications where moisture or contaminants may be present. The stainless steel construction also enables the tube to withstand high-velocity airflows without risk of damage, providing long-lasting performance in both indoor and outdoor settings. -
Question:
How do you calibrate the Dwyer Instruments 160-18 Pitot Tube?
Answer: Calibrating the Dwyer 160-18 Pitot Tube involves using a reference air speed source. You should connect the Pitot Tube to a manometer or differential pressure gauge to measure the pressure difference created by the airflow. By adjusting the readings from the manometer, you can determine the calibration factor. Regular calibration ensures the accuracy of measurements, especially when used in critical applications where precision is essential. -
Question:
What is the maximum airflow speed that the Dwyer 160-18 Pitot Tube can measure?
Answer: The Dwyer 160-18 Pitot Tube is designed to measure airflow at velocities up to 90 feet per second. This capability makes it suitable for a wide range of applications, from residential HVAC systems to larger industrial systems. Ak accuracy in capturing high-speed airflows allows technicians to troubleshoot system inefficiencies and make necessary adjustments for optimal operation. -
Question:
Does the Dwyer 160-18 Pitot Tube require any special maintenance?
Answer: Maintaining the Dwyer 160-18 Pitot Tube generally involves routine cleaning and inspection. It’s recommended to check for blockages in the openings, which can affect measurement accuracy. Regular cleaning with mild detergents will help ensure the longevity and consistent performance of the tube. Proper handling and storage away from extreme conditions will also enhance durability, especially if used frequently in demanding environments. -
Question:
Are there any accessories available for the Dwyer Instruments 160-18 Pitot Tube?
Answer: Yes, several accessories can enhance the use of the Dwyer 160-18 Pitot Tube. Common accessories include a differential pressure gauge, flexible tubing for remote readings, and protective cases. These tools can help provide better measurements and increase the versatility of the Pitot Tube in different conditions. Using the right accessories can also simplify the setup process, making fieldwork more efficient. -
Question:
What is the operating temperature range for the Dwyer 160-18 Pitot Tube?
Answer: The Dwyer 160-18 Pitot Tube operates effectively in a temperature range of -40 to 200 degrees Fahrenheit. This wide range allows it to be used in various environments, from chilled air systems to hot air ducts. Knowing the operating temperature range helps users determine suitable applications and ensures optimal performance, especially in variable weather conditions. -
Question:
What is the length and diameter of the Dwyer Instruments 160-18 Pitot Tube?
Answer: The Dwyer 160-18 Pitot Tube measures 18 inches in length with a diameter that typically fits standard duct sizes. The length provides sufficient reach for deeper duct systems, while the diameter ensures compatibility with HVAC equipment. This size makes the Pitot Tube practical for both residential and commercial applications, allowing users to perform airflow measurements in various duct configurations. -
Question:
Can the Dwyer 160-18 Pitot Tube be used in corrosive environments?
Answer: The Dwyer 160-18 Pitot Tube's stainless steel construction makes it resistant to rust and corrosion, which allows it to withstand exposure to mildly corrosive environments. However, extreme corrosive substances may still affect its longevity. For applications in highly corrosive settings, consider using specialized materials or coatings to enhance protection. This versatility allows users to adapt the instrument for a variety of challenging conditions. -
Question:
Where can I buy Dwyer Instruments, Inc. 160-18 18 SS Pitot Tube in Kiribati?
Answer: You can purchase the Dwyer Instruments, Inc. 160-18 18 SS Pitot Tube from Ubuy, a reliable online shopping platform that offers various products across different categories. Ubuy ensures a convenient shopping experience, providing product details, user reviews, and often multiple payment options to cater to your preferences. Shopping on Ubuy allows you to find the specific item you're looking for while enjoying a smooth and secure check-out process.
Dwyer Anemometers Editorial Review
Customer Reviews & Ratings
-
5 Star
100%
-
4 Star
0%
-
3 Star
0%
-
2 Star
0%
-
1 Star
0%
Review this product
Share your thoughts with other customers
Platform Trust & Buyer Confidence
“The product received very good packaging & safe…Thank You”
“Accurate delivery timing given”
“Not madly expensive like I thought, and much quicker than promised.”
“Never dealt with Ubuy before, but everything worked out great. Seamless cross border purchasing and shipping. Thanks!”
“The process was smooth, with clear communication and timelines. This was my 1st purchase and I am really impressed. I will definitely be coming back.”
Product Price History
Important information
- Limitations : For products shipped internationally, please note that any manufacturer warranty may not be valid; manufacturer service options may not be available; product manuals, instructions, and safety warnings may not be in destination country languages; the products (and accompanying materials) may not be designed in accordance with destination country standards, specifications, and labeling requirements; and the products may not conform to destination country voltage and other electrical standards (requiring use of an adapter or converter if appropriate). The recipient is responsible for assuring that the product can be lawfully imported to the destination country. When ordering from Ubuy or its affiliates, the recipient is the importer of record and must comply with all laws and regulations of the destination country.
- Not all the products listed on Ubuy are for sale, as Ubuy is a global search engine. Products are subject to export/trade regulations.
AUD 399
Order now and get it around Saturday, July 11
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
PCI DSS compliant and ISO 27001:2022 certified, with encrypted payments and full buyer protection on every order.
Features & Benefits
- No calibration needed
- Precisely located, burr-free static pressure holes
- Hemispherical tip design for accuracy if imperfectly aligned
- Nearly impossible to damage
- 304 stainless steel construction
- Meets ASME, AMCA, and ASHRAE standards